Kew Mate 2001 AC/DC Digital Multimter with open-jaw current clamp 3400-count LCD with bargraph display AC and DC current measu********* Pocket-sized with heavy-duty case design Auto-ranging, with data-hold and range-hold functions Sleep function to save battery consumption Function Measurement ranges Accuracy DC Voltage 340mV, 3.4V, 34V, 340V, 600V ± (1.5% reading + 4 digits) AC Voltage (50–400Hz) 3.4V, 34V, 340V, 600V ± (1.5% reading + 5 digits) DC Current 60A (KM2000), 100A (KM2001) ± (2% reading + 5 digits) AC Current (50–60 Hz) 60A (KM2000), 100A (KM2001) ± (2% reading + 5 digits) Frequency, AC voltage 3.4 kHz, 34 kHz, 300 kHz ± (0.1% reading + 1 digit) Frequency, AC current 3.4 kHz, 10 kHz ± (0.1% reading + 1 digit) Resistance 340Ω, 3.4kΩ, 34kΩ, 340kΩ ± (1% reading + 3 digits) 3.4MΩ ± (5% reading + 5 digits) 340MΩ ± (15% reading + 5 digits) Continuity buzzer Sounds at <30Ω on 340Ω range ± 10Ω Maximum circuit voltage 600Vac/dc (between line/neutral) 300Vac/dc (against earth) Conductor size, AC/DC current Maximum Ø 6mm (KM2000) 10mm (KM2001) Withstand voltage 3700Vac for 1 minute Power Source Two R03 or equivalent (AAA 1.5V) batteries Size (LxWxD) and Weight 128 x 91 x 27 mm, approx. 220 g Standards IEC61010-1 CAT III 300V Pollution Degree 2, IEC61010-2-031, IEC61010-2-032, IEC61326-1