The Atlas Copco QAS diesel generator range has taken a major step forward for easy installation, high performance, maintenance efficiency and reduced noise. The QAS 400 has 400kVa of power and 83L/h (100% load) fuel consumption. QAS portable and stationary diesel generators are are designed to be moved regularly. Whether that be a few metres or hundreds of kilometres, you can be assured of their easy, safe movement capabilities and guaranteed performance, even in the harshest conditions. This makes the QAS perfect for rental applications and heavy duty construction use. When you need power, maybe a single generator is not always the most efficient solution. Does the application load vary? Do you need prime power for long term projects on a remote site? Do you need a semi-permanent installation that can be upgraded or downgraded? FREE POWER PLAN AND ADVICE QAS400 – 400kVa Portable & Stationary Generator Features High-quality components Easy to transport, install and use Excellent accessibility and superior serviceability Quiet generator QAS400 – 400kVa Portable & Stationary Generator Downloads QAS Generators Brochure Quick Spec Prime Power 400kVa Fuel Consumption 83L/h (100% Load) Engine Volvo Alternator Leroy Somer QAS400 – 400kVa Portable & Stationary Generator Applications & Gallery Make the Perfect Power When you need power, maybe a single generator is not always the most efficient solution. Does the application load vary? Do you need prime power for long term projects on a remote site? Do you need a semi- permanent installation that can be upgraded or downgraded? A Modular Power Plant (or paralleling multiple generators) is the efficient solution if you answered yes to any of the above questions. Simply, this is a configuration of generators working together. We have developed a unique Power Management System (PMS). The PMS system enables the optimisation of fuel consumption and expands the generator’s lifetime. PMS manages the quantity of generators running in parallel with load demand, starting and stopping units in line with increases or decreases in load. In this way, the load on each generator remains at a level which optimises fuel consumption. It also eliminates the need for generators to run with low load levels, which can cause engine damage and shorten the life expectancy of the equipment. Integrated Control and Power Cubicle • Qc1103 island mode (remote start) digital controller • 4 Pole breaker with B-curve • Earth leakage protection • Dedicated socket compartment • Emergency stop Superior Accessibility • 1-side serviceability (control panel side) through big access doors and panels • Access to alternator (AVR and diode bridge) • Full access to engine • Direct radiator cleaning access • External drain points access Installation Efficiency • Plug and play cable connection • Pass through cable path, natural bend and strain relief • Plexi cover for terminal board protection Transport Efficiency • Integrated lifting structure with single elevation point • Sturdy multidrop base frame with integrated forklift pockets • 110% self containment Performance • High cooling performance radiator with ParCOOL for 100% prime power operation • Sound attenuated and rugged galvanized steel enclosure Service Efficiency • Decreased service downtime due to heavy duty fuel filtration system with water separator • Extend engine life time because of Dual Stage Air Filter with safety cartrige • Oil drain pump • Lockable external fuel filling point Electrical Options • Qc2103TM (AMF controller) • Qc4003TM (Paralleling applications controller) • Dual frequency with switch • Insulation monito********* urations (dedicated frequency) • 1-phase socket 16 A (RIM, PIN or CEE version) • Neutral EDF • PMG alternator • Battery charger and battery cut-off switch • Coolant heater • Multi voltage variant with voltage selector Mechanical Options • Quick couplings for external fuel tank connection • Frame with integrated long autonomy fuel tank • Undercarriage adjustable towbar with brakes • Towing eyes • Refinery equipment (spark arrestor and air shut off valve) • Cold start (synthetic oil filling) • Cold flow (fuel additive) • Custom colors
Location: Rocklea, Brisbane South West, Brisbane Region, Queensland
Contact No. *******3782 View
The Atlas Copco QAS diesel generator range has taken a major step forward for easy installation, high performance, maintenance efficiency and reduced noise. The QAS 400 has 400kVa of power and 83L/h (100% load) fuel consumption.
QAS portable and stationary diesel generators are are designed to be moved regularly. Whether that be a few metres or hundreds of kilometres, you can be assured of their easy, safe movement capabilities and guaranteed performance, even in the harshest conditions.
This makes the QAS perfect for rental applications and heavy duty construction use.
When you need power, maybe a single generator is not always the most efficient solution. Does the application load vary? Do you need prime power for long term projects on a remote site? Do you need a semi-permanent installation that can be upgraded or downgraded?
FREE POWER PLAN AND ADVICE
QAS400 – 400kVa Portable & Stationary Generator Features
High-quality components
Easy to transport, install and use
Excellent accessibility and superior serviceability
Quiet generator
QAS400 – 400kVa Portable & Stationary Generator Downloads
QAS Generators Brochure
Quick Spec
Prime Power
400kVa
Fuel Consumption
83L/h (100% Load)
Engine
Volvo
Alternator
Leroy Somer
QAS400 – 400kVa Portable & Stationary Generator Applications & Gallery
Make the Perfect Power
When you need power, maybe a single generator is not always the most efficient solution. Does the application load vary? Do you need prime power for long term projects on a remote site? Do you need a semi- permanent installation that can be upgraded or downgraded?
A Modular Power Plant (or paralleling multiple generators) is the efficient solution if you answered yes to any of the above questions. Simply, this is a configuration of generators working together.
We have developed a unique Power Management System (PMS). The PMS system enables the optimisation of fuel consumption and expands the generator’s lifetime. PMS manages the quantity of generators running in parallel with load demand, starting and stopping units in line with increases or decreases in load. In this way, the load on each generator remains at a level which optimises fuel consumption. It also eliminates the need for generators to run with low load levels, which can cause engine damage and shorten the life expectancy of the equipment.
Integrated Control and Power Cubicle
• Qc1103 island mode (remote start) digital controller
• 4 Pole breaker with B-curve
• Earth leakage protection
• Dedicated socket compartment
• Emergency stop
Superior Accessibility
• 1-side serviceability (control panel side) through big access doors and panels
• Access to alternator (AVR and diode bridge)
• Full access to engine
• Direct radiator cleaning access
• External drain points access
Installation Efficiency
• Plug and play cable connection
• Pass through cable path, natural bend and strain relief
• Plexi cover for terminal board protection
Transport Efficiency
• Integrated lifting structure with single elevation point
• Sturdy multidrop base frame with integrated forklift pockets
• 110% self containment
Performance
• High cooling performance radiator with ParCOOL for 100% prime power operation
• Sound attenuated and rugged galvanized steel enclosure
Service Efficiency
• Decreased service downtime due to heavy duty fuel filtration system with water separator
• Extend engine life time because of Dual Stage Air Filter with safety cartrige
• Oil drain pump
• Lockable external fuel filling point
Electrical Options
• Qc2103TM (AMF controller)
• Qc4003TM (Paralleling applications controller)
• Dual frequency with switch
• Insulation monitoring relay
• 3-phase sockets configurations (dedicated frequency)
• 1-phase socket 16 A (RIM, PIN or CEE version)
• Neutral EDF
• PMG alternator
• Battery charger and battery cut-off switch
• Coolant heater
• Multi voltage variant with voltage selector
Mechanical Options
• Quick couplings for external fuel tank connection
• Frame with integrated long autonomy fuel tank
• Undercarriage adjustable towbar with brakes
• Towing eyes
• Refinery equipment (spark arrestor and air shut off valve)
• Cold start (synthetic oil filling)
• Cold flow (fuel additive)
• Custom colors
When you call, Don't forget to mention ADSCT whenever you will call to user. Be safe during payment.