Special version for Australia & NZ with Australian Phase colours and Software with Australian standards ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS A STANDARD Power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 64 V to 760 V. With particular emphasis on measurements at low voltage poles, due to the ease of connection. Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits. Remote control and data transfer through a built-in GSM modem (GPRS). Anti-theft feature - SMS notification in the event of position change - built-in GPS receiver. Real-time clock synchronized to GPS protocol. Live mode oscilloscope display Colour LCD display of real time measurements & vector diagram 600V CAT IV IP65 weatherproof Wireless & USB communication Possible measurements: Measurements according to EN 50160 & Australian standards Voltage L1, L2, L3, N-PE - average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers, Current L1, L2, L3, N (four inputs) - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers, Crest factor for voltage and current, Frequency from 40Hz to 70Hz , Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive), Power recording: - Budeanu method, - IEEE 1459, Active, reactive, apparent energy, Power factor, cosφ, tgφ, K factor (transformer overload caused by the harmonics), Up to 50th harmonics for voltage and current, Total Harmonic Distortion (THD) for voltage and current, Short-term (PST) and long-term (PLT) flicker, Unbalance of voltage and current, Current events detection including waveforms recording, Current and voltage waveforms recording after each averaging period. The device is designed to work with networks: with nominal frequency 50/60Hz, with nominal voltage: 64/110 V; 110/190 V; 115/200 V; 127/220 V; 220/380 V; 230/400 V; 240/415 V; 254/440 V; 290/500 V; 400/690 V, DC network Supported networks: single-phase, two-phase with common N conductor, three-phase star connection with and without N conductor, three-phase delta. Includes: 4x Flexible clamps (Rogowski coil) 3,000A AC (length: 45 cm), 4x 3m permanently fixed voltage leads, 4 small crocodile clips black, blue, white red, 4x large black crocodile clips, Mains plug with banana inputs (L1 and N) for connecting the analyzer to a socket in order to charge the battery, Sonel Analysis 2 software, USB cable, USB wireless module, Soft bag, pole straps, Pole mounting kit, DIN mounting kit, Built-in Li-Ion rechargeable battery, Operating manual, Calibration certificate.
Location: 7 Anella Ave 7 Anella Ave, Castle Hill NSW 2154, Australia
N/A
When you call, Don't forget to mention ADSCT whenever you will call to user. Be safe during payment.