PAC3760 DL Logging Appliance and RCD Tester The PAC3760 DL includes download of test results to any spreadsheet or database program, no special software required. The PAC3760 DL conducts earth bond, insulation, polarity, portable RCD tests and fixed RCD tests, as well as Leakage Current Tests for Class I and Class II appliances and 3 phase appliances with optional adaptors. Display LCD Indication PASS/FAIL and Measured Values Operation 6 Push Button Insulation test: Test Range 500V DC, 1Mohm at rated mains supply, Pass Level 1Mohm Earth continuity test: Test Current 200mA, Pass Level 1ohm Leakage test: Output Voltage 240V AC, Pass Level Class I 5mA, Class II 1mA Single push button operation Battery and mains powered Pass/Fail indication and actual readings Senses an IEC or extension lead and conducts a polarity test Detects if the appliance under test is not switched "On" 10mA and 30mA portable and fixed RCD trip time tests In-Built isolation transformer Stores 999 test results and downloads CSV file "Plug N Print" test tag printing - optional PAC-OPT test tag printer Supplied with Padded carry case, earth bond clip, IEC adaptor, mains supply test lead.
Location: Sydney 25 Pavesi Street Smithfield NSW 2164
N/A
When you call, Don't forget to mention ADSCT whenever you will call to user. Be safe during payment.